    电采暖锅炉防腐保养有哪些方法?
    来源:http://www.jnlzsb.com 发布时间:2021-05-24

    电采暖锅炉防腐保养有哪些办法?不管是什么样的锅炉,在经过长时刻的运用之后,锅炉里边都会发作许多化学反响,而且依据锅炉所用水质的不同,锅炉里边发作的化学反响也各不相同,而多种化学物质长时直接受高温高湿度的环境就简略发作许多化学反响。
    Electric heating boiler anticorrosion maintenance what methods? No matter what kind of boiler, after a long time of use, there will be a lot of chemical reactions in the boiler, and according to the different water quality used in the boiler, the chemical reactions in the boiler are also different, and a variety of chemical substances are directly affected by the high temperature and high humidity environment for a long time.
    这就要求咱们往常在运用进程中,以及经过长时刻停用时,需求十分留心锅炉炉体表里的防腐保养。锅炉的保养特别是锅炉停炉之后的保养,应当留心的是,首要在锅炉停炉冷 却后有必要要彻 底铲除受热面的积灰和炉排上部以及炉体下部的灰渣,这样能坚持烟道有必定的天然通风。
    This requires us to pay close attention to the anti-corrosion maintenance on the surface of the boiler body in the process of application and after a long period of shutdown. The maintenance of boiler, especially after boiler shutdown, should pay attention to the fact that it is necessary to thoroughly remove the ash on the heating surface and the ash on the upper part of the grate and the lower part of the furnace body after boiler shutdown cooling, so as to ensure that the flue has certain natural ventilation.
    一般情况下为了防止炉体受潮应在炉膛和烟道中放置单调剂。如以生石灰作为单调剂则每立方米炉膛或烟道内一般应放置3kg左右。放置后应该紧密封闭一切的通风门。生石灰变粉后要替换如锅炉房方位低洼,停炉期间地上泛潮严峻的时分应该选用常常小火烘烤和放置单调剂相结合的办法。
    In general, in order to prevent the furnace body from being affected with moisture, a single regulator should be placed in the furnace and flue. If quicklime is used as monotone agent, about 3kg should be placed in furnace or flue per cubic meter. All ventilation doors should be closed tightly after placing. If the boiler room is low-lying and the ground is flooded seriously during the shutdown period, the combination of low fire baking and placing monotone agent should be used.
    (1)锅炉房一般应独自设置,但不得设置在人口稠密的区域(或毗连)。锅炉房应为、二级防火修建。锅炉房不能燃煤,总额外蒸腾量不超越每小时4吨,可选用三级防火修建,但应留心其烟囱和屋顶可燃结构。它们之间的间隔不该小于50厘米。
    (1) The environment-friendly boiler room should be set up alone, but not in densely populated areas (or adjacent). The boiler room shall be built for class II and class II fire protection. The boiler room can't burn coal, and the total transpiration is not more than 4 tons per hour. It can be built with three-level fire protection, but the chimney and roof combustible structure should be paid attention to. The distance between them should not be less than 50 cm.
    (2)应在主楼的顺风或侧风方向挑选锅炉房。依据《修制造计防火规范》的有关规矩,能够承认与周围易燃的、风险修建以及锅炉房和煤堆,锅炉房和油(气)罐等的防火间隔间隔。
    (2) The environment-friendly boiler room should be selected in the downwind or crosswind direction of the main building. According to the relevant rules of the code for fire protection of repair and manufacturing engineering, it can be recognized that the fire separation with the surrounding flammable and risky buildings, as well as the boiler room and coal pile, boiler room and oil (gas) tank, etc.
    (3)锅炉房为轻型房子,每屋顶不超越120公斤。当锅炉房安顿成多层时,每层楼的每侧应少有一个出口,而且有一个安 全的疏散楼梯抵达每层楼的操作点。通往锅炉房室外的门应向外翻开,作业室或客厅的门应通向锅炉内部,一切出进口和通道应坚持晓畅。可是,与锅炉房相邻的压力调度室应由防火墙离隔,其门窗应向外开,不得直接通向锅炉房。
    (3) The environment-friendly boiler room is a light-weight house with no more than 120 kg per roof. When the boiler room is installed in multiple floors, there should be at least one exit on each side of each floor, and there should be a safe evacuation staircase to reach the operation point of each floor. The door leading to the outside of the boiler room should be opened outwards, the door of the working room or living room should lead to the inside of the boiler, and all the entrances, exits and passages should be clear. However, the pressure control room adjacent to the boiler room should be separated by a firewall, and its doors and windows should be opened outwards instead of directly leading to the boiler room.
    (4)应恰当挑选渣场的方位,并制造围墙。在锅炉房25米规划内不得制造易燃结构或堆积易燃资料。
    (4) The location of the environmental protection slag yard should be properly selected and the enclosure should be made. It is not allowed to make flammable structures or accumulate flammable materials within 25m of the boiler room.
    (5)锅炉房的电源线应选用金属外壳或电缆接线,不得沿热载体外表敷设或经过煤场下方。禁止在室内堆积可燃资料。
    (5) The power line of the environmental protection boiler room shall be connected with metal shell or cable, and shall not be laid along the surface of the heat carrier or under the coal yard. It is forbidden to accumulate combustible materials indoors.